{"id":185,"date":"2019-09-11T09:14:25","date_gmt":"2019-09-11T16:14:25","guid":{"rendered":"https:\/\/airmonitor.millermediallc.com\/hvac\/?post_type=product&#038;p=185"},"modified":"2020-03-31T08:06:55","modified_gmt":"2020-03-31T15:06:55","slug":"electra-flofi-thermal-fan-inlet-probes","status":"publish","type":"product","link":"https:\/\/www.airmonitor.com\/hvac\/product\/electra-flofi-thermal-fan-inlet-probes\/","title":{"rendered":"ELECTRA-flo\/FI Thermal Dispersion Fan Inlet Probe Array"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"<p>The ELECTRA-flo\/FI Thermal Fan Inlet Airflow Probe utilizes dual point thermal dispersion technology sensors installed in the fan&#8217;s inlet bell mouth at the throat. Aerodynamic sensor apertures, assisted by the air processing effect of the nozzle-shaped fan inlet, provide accurate measurement for most fan types. Readings are taken at the measurement point, not calculated at the transmitter. This allows for daisy-chaining multiple units together which reduces cabling. Anodized aluminum sensor housings and stainless steel adjustable support struts are both durable and easy to install. ELECTRA-flo sensors are factory calibrated to NIST traceable standards, and each fan inlet assembly comes complete with an ELECTRA-flo transmitter for local data display, performing configuration and calibration, and to provide analog outputs of airflow and temperature.<\/p>\n","protected":false},"featured_media":186,"template":"","meta":{"_acf_changed":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":""},"product_brand":[],"product_cat":[30],"product_tag":[],"class_list":{"0":"post-185","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-thermal-dispersion-measurement","7":"product_application-building-airflow-measurement-control","8":"product_application-building-space-pressurization","9":"product_application-fan-inlet-measurement","10":"product_application-fan-tracking-for-building-pressurization","11":"product_application-indoor-air-quality","12":"entry","14":"first","15":"instock","16":"shipping-taxable","17":"product-type-simple"},"acf":[],"featured_image_urls_v2":{"full":["https:\/\/www.airmonitor.com\/hvac\/wp-content\/uploads\/sites\/2\/electra-flo-fI-with-transmitter.png",600,600,false],"thumbnail":["https:\/\/www.airmonitor.com\/hvac\/wp-content\/uploads\/sites\/2\/electra-flo-fI-with-transmitter-150x150.png",150,150,true],"medium":["https:\/\/www.airmonitor.com\/hvac\/wp-content\/uploads\/sites\/2\/electra-flo-fI-with-transmitter-300x300.png",300,300,true],"medium_large":["https:\/\/www.airmonitor.com\/hvac\/wp-content\/uploads\/sites\/2\/electra-flo-fI-with-transmitter.png",600,600,false],"large":["https:\/\/www.airmonitor.com\/hvac\/wp-content\/uploads\/sites\/2\/electra-flo-fI-with-transmitter.png",600,600,false],"1536x1536":["https:\/\/www.airmonitor.com\/hvac\/wp-content\/uploads\/sites\/2\/electra-flo-fI-with-transmitter.png",600,600,false],"2048x2048":["https:\/\/www.airmonitor.com\/hvac\/wp-content\/uploads\/sites\/2\/electra-flo-fI-with-transmitter.png",600,600,false],"sidebar-featured":["https:\/\/www.airmonitor.com\/hvac\/wp-content\/uploads\/sites\/2\/electra-flo-fI-with-transmitter-75x75.png",75,75,true],"product-application-square":["https:\/\/www.airmonitor.com\/hvac\/wp-content\/uploads\/sites\/2\/electra-flo-fI-with-transmitter-300x300.png",300,300,true],"gb-block-post-grid-landscape":["https:\/\/www.airmonitor.com\/hvac\/wp-content\/uploads\/sites\/2\/electra-flo-fI-with-transmitter.png",400,400,false],"gb-block-post-grid-square":["https:\/\/www.airmonitor.com\/hvac\/wp-content\/uploads\/sites\/2\/electra-flo-fI-with-transmitter.png",600,600,false],"woocommerce_thumbnail":["https:\/\/www.airmonitor.com\/hvac\/wp-content\/uploads\/sites\/2\/electra-flo-fI-with-transmitter-500x500.png",500,500,true],"woocommerce_single":["https:\/\/www.airmonitor.com\/hvac\/wp-content\/uploads\/sites\/2\/electra-flo-fI-with-transmitter.png",600,600,false],"woocommerce_gallery_thumbnail":["https:\/\/www.airmonitor.com\/hvac\/wp-content\/uploads\/sites\/2\/electra-flo-fI-with-transmitter-180x180.png",180,180,true],"gform-image-choice-sm":["https:\/\/www.airmonitor.com\/hvac\/wp-content\/uploads\/sites\/2\/electra-flo-fI-with-transmitter.png",300,300,false],"gform-image-choice-md":["https:\/\/www.airmonitor.com\/hvac\/wp-content\/uploads\/sites\/2\/electra-flo-fI-with-transmitter.png",400,400,false],"gform-image-choice-lg":["https:\/\/www.airmonitor.com\/hvac\/wp-content\/uploads\/sites\/2\/electra-flo-fI-with-transmitter.png",600,600,false]},"post_excerpt_stackable_v2":"<p>The ELECTRA-flo\/FI Thermal Fan Inlet Airflow Probe utilizes dual point thermal dispersion technology sensors installed in the fan&#8217;s inlet bell mouth at the throat. Aerodynamic sensor apertures, assisted by the air processing effect of the nozzle-shaped fan inlet, provide accurate measurement for most fan types. Readings are taken at the measurement point, not calculated at the transmitter. This allows for daisy-chaining multiple units together which reduces cabling. Anodized aluminum sensor housings and stainless steel adjustable support struts are both durable and easy to install. ELECTRA-flo sensors are factory calibrated to NIST traceable standards, and each fan inlet assembly comes complete with an ELECTRA-flo transmitter for local data display, performing configuration and calibration, and to provide analog outputs of airflow and temperature.<\/p>\n","category_list_v2":"","author_info_v2":{"name":"","url":""},"comments_num_v2":"0 comments","yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>ELECTRA-flo\/FI Thermal Dispersion Fan Inlet Probe Array - HVAC | Air Monitor<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.airmonitor.com\/hvac\/product\/electra-flofi-thermal-fan-inlet-probes\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ELECTRA-flo\/FI Thermal Dispersion Fan Inlet Probe Array - HVAC | Air Monitor\" \/>\n<meta property=\"og:description\" content=\"The ELECTRA-flo\/FI Thermal Fan Inlet Airflow Probe utilizes dual point thermal dispersion technology sensors installed in the fan&#039;s inlet bell mouth at the throat. Aerodynamic sensor apertures, assisted by the air processing effect of the nozzle-shaped fan inlet, provide accurate measurement for most fan types. Readings are taken at the measurement point, not calculated at the transmitter. This allows for daisy-chaining multiple units together which reduces cabling. Anodized aluminum sensor housings and stainless steel adjustable support struts are both durable and easy to install. ELECTRA-flo sensors are factory calibrated to NIST traceable standards, and each fan inlet assembly comes complete with an ELECTRA-flo transmitter for local data display, performing configuration and calibration, and to provide analog outputs of airflow and temperature.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.airmonitor.com\/hvac\/product\/electra-flofi-thermal-fan-inlet-probes\/\" \/>\n<meta property=\"og:site_name\" content=\"HVAC | Air Monitor\" \/>\n<meta property=\"article:modified_time\" content=\"2020-03-31T15:06:55+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.airmonitor.com\/hvac\/wp-content\/uploads\/sites\/2\/electra-flo-fI-with-transmitter.png\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.airmonitor.com\/hvac\/product\/electra-flofi-thermal-fan-inlet-probes\/\",\"url\":\"https:\/\/www.airmonitor.com\/hvac\/product\/electra-flofi-thermal-fan-inlet-probes\/\",\"name\":\"ELECTRA-flo\/FI Thermal Dispersion Fan Inlet Probe Array - HVAC | Air Monitor\",\"isPartOf\":{\"@id\":\"https:\/\/www.airmonitor.com\/hvac\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.airmonitor.com\/hvac\/product\/electra-flofi-thermal-fan-inlet-probes\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.airmonitor.com\/hvac\/product\/electra-flofi-thermal-fan-inlet-probes\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.airmonitor.com\/hvac\/wp-content\/uploads\/sites\/2\/electra-flo-fI-with-transmitter.png\",\"datePublished\":\"2019-09-11T16:14:25+00:00\",\"dateModified\":\"2020-03-31T15:06:55+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.airmonitor.com\/hvac\/product\/electra-flofi-thermal-fan-inlet-probes\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.airmonitor.com\/hvac\/product\/electra-flofi-thermal-fan-inlet-probes\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.airmonitor.com\/hvac\/product\/electra-flofi-thermal-fan-inlet-probes\/#primaryimage\",\"url\":\"https:\/\/www.airmonitor.com\/hvac\/wp-content\/uploads\/sites\/2\/electra-flo-fI-with-transmitter.png\",\"contentUrl\":\"https:\/\/www.airmonitor.com\/hvac\/wp-content\/uploads\/sites\/2\/electra-flo-fI-with-transmitter.png\",\"width\":600,\"height\":600,\"caption\":\"ELECTRA-flo\/FI Thermal Fan Inlet Airflow Measurement Probe\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.airmonitor.com\/hvac\/product\/electra-flofi-thermal-fan-inlet-probes\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.airmonitor.com\/hvac\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"HVAC Products\",\"item\":\"https:\/\/www.airmonitor.com\/hvac\/products\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"ELECTRA-flo\/FI Thermal Dispersion Fan Inlet Probe Array\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.airmonitor.com\/hvac\/#website\",\"url\":\"https:\/\/www.airmonitor.com\/hvac\/\",\"name\":\"HVAC | Air Monitor\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.airmonitor.com\/hvac\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ELECTRA-flo\/FI Thermal Dispersion Fan Inlet Probe Array - HVAC | Air Monitor","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.airmonitor.com\/hvac\/product\/electra-flofi-thermal-fan-inlet-probes\/","og_locale":"en_US","og_type":"article","og_title":"ELECTRA-flo\/FI Thermal Dispersion Fan Inlet Probe Array - HVAC | Air Monitor","og_description":"The ELECTRA-flo\/FI Thermal Fan Inlet Airflow Probe utilizes dual point thermal dispersion technology sensors installed in the fan's inlet bell mouth at the throat. Aerodynamic sensor apertures, assisted by the air processing effect of the nozzle-shaped fan inlet, provide accurate measurement for most fan types. Readings are taken at the measurement point, not calculated at the transmitter. This allows for daisy-chaining multiple units together which reduces cabling. Anodized aluminum sensor housings and stainless steel adjustable support struts are both durable and easy to install. ELECTRA-flo sensors are factory calibrated to NIST traceable standards, and each fan inlet assembly comes complete with an ELECTRA-flo transmitter for local data display, performing configuration and calibration, and to provide analog outputs of airflow and temperature.","og_url":"https:\/\/www.airmonitor.com\/hvac\/product\/electra-flofi-thermal-fan-inlet-probes\/","og_site_name":"HVAC | Air Monitor","article_modified_time":"2020-03-31T15:06:55+00:00","og_image":[{"width":600,"height":600,"url":"https:\/\/www.airmonitor.com\/hvac\/wp-content\/uploads\/sites\/2\/electra-flo-fI-with-transmitter.png","type":"image\/png"}],"twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.airmonitor.com\/hvac\/product\/electra-flofi-thermal-fan-inlet-probes\/","url":"https:\/\/www.airmonitor.com\/hvac\/product\/electra-flofi-thermal-fan-inlet-probes\/","name":"ELECTRA-flo\/FI Thermal Dispersion Fan Inlet Probe Array - HVAC | Air Monitor","isPartOf":{"@id":"https:\/\/www.airmonitor.com\/hvac\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.airmonitor.com\/hvac\/product\/electra-flofi-thermal-fan-inlet-probes\/#primaryimage"},"image":{"@id":"https:\/\/www.airmonitor.com\/hvac\/product\/electra-flofi-thermal-fan-inlet-probes\/#primaryimage"},"thumbnailUrl":"https:\/\/www.airmonitor.com\/hvac\/wp-content\/uploads\/sites\/2\/electra-flo-fI-with-transmitter.png","datePublished":"2019-09-11T16:14:25+00:00","dateModified":"2020-03-31T15:06:55+00:00","breadcrumb":{"@id":"https:\/\/www.airmonitor.com\/hvac\/product\/electra-flofi-thermal-fan-inlet-probes\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.airmonitor.com\/hvac\/product\/electra-flofi-thermal-fan-inlet-probes\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.airmonitor.com\/hvac\/product\/electra-flofi-thermal-fan-inlet-probes\/#primaryimage","url":"https:\/\/www.airmonitor.com\/hvac\/wp-content\/uploads\/sites\/2\/electra-flo-fI-with-transmitter.png","contentUrl":"https:\/\/www.airmonitor.com\/hvac\/wp-content\/uploads\/sites\/2\/electra-flo-fI-with-transmitter.png","width":600,"height":600,"caption":"ELECTRA-flo\/FI Thermal Fan Inlet Airflow Measurement Probe"},{"@type":"BreadcrumbList","@id":"https:\/\/www.airmonitor.com\/hvac\/product\/electra-flofi-thermal-fan-inlet-probes\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.airmonitor.com\/hvac\/"},{"@type":"ListItem","position":2,"name":"HVAC Products","item":"https:\/\/www.airmonitor.com\/hvac\/products\/"},{"@type":"ListItem","position":3,"name":"ELECTRA-flo\/FI Thermal Dispersion Fan Inlet Probe Array"}]},{"@type":"WebSite","@id":"https:\/\/www.airmonitor.com\/hvac\/#website","url":"https:\/\/www.airmonitor.com\/hvac\/","name":"HVAC | Air Monitor","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.airmonitor.com\/hvac\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.airmonitor.com\/hvac\/wp-json\/wp\/v2\/product\/185","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.airmonitor.com\/hvac\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.airmonitor.com\/hvac\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.airmonitor.com\/hvac\/wp-json\/wp\/v2\/media\/186"}],"wp:attachment":[{"href":"https:\/\/www.airmonitor.com\/hvac\/wp-json\/wp\/v2\/media?parent=185"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.airmonitor.com\/hvac\/wp-json\/wp\/v2\/product_brand?post=185"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.airmonitor.com\/hvac\/wp-json\/wp\/v2\/product_cat?post=185"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.airmonitor.com\/hvac\/wp-json\/wp\/v2\/product_tag?post=185"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}